Hum, Buzz and Ground Loops in Audio Systems

A systematic way to find the source of hum or buzz in an audio system, and the transformer specification that removes it — without guessing at filters and grounding schemes.

The symptom

Hum is usually a steady 50 Hz or 60 Hz tone with harmonics underneath. Buzz is the harsher, higher-frequency version. Both appear or disappear depending on which cable you unplug, which is the clue that tells you what kind of problem you have.

The four causes worth checking in order

  1. Ground loop. Two units earthed at different potentials; current flows through the cable shield. Unplugging one source stops it → ground loop.
  2. Stray magnetic field. An EI power transformer too close to an input stage or a signal transformer. It changes with load, not with grounding → radiated field.
  3. Capacitive coupling. High inter-winding capacitance passes mains-borne noise into the audio path. It gets worse at high frequencies → coupling, not loop.
  4. Supply ripple. Insufficient smoothing or poor regulation shows as hum that tracks the volume control → power supply, not wiring.

The transformer fixes

  • 1:1 isolation transformer to break a ground loop galvanically while passing the signal. The loop stops existing; no current can flow through the shield.
  • Electrostatic (Faraday) shield between primary and secondary, bonded to a separate lead, to shunt mains-borne noise to chassis.
  • Bifilar or symmetrical windings for balanced circuits, with matched DC resistance on both halves.
  • Toroidal core to keep stray flux inside the winding, so the transformer can sit near low-level circuitry.
  • Potted metal can when the unit must also be mechanically silent and moisture-proof.

What to send us

Signal level and impedance on each side, the frequency band that must pass (for example 20 Hz–20 kHz), the isolation voltage required, whether the shield needs its own lead, and the space available. We reply with a winding proposal and a prototype can be built in 7–10 days.

Related pages

Talk to an engineer

Describe the symptom you are chasing — the noise, the trip, the heat, the space you have — and we will come back with a transformer proposal rather than a catalogue part. Send drawings or a target price and we normally reply within 24 hours on working days.

Contact our sales engineers →  |  Request a formal quotation →

Why NRE

NRE has manufactured transformers since 1994, with plants in Guangdong and Hubei covering nearly 100 mu and 62,700 m². Annual capacity is about 8 million toroidal transformers, 30 million EI transformers and 200,000 special transformers, with close to 150 engineers on the design and process side. We build to print, to specification, or from a problem description.